Simple Structure Freezer Condensing Unit Easy For Installation And Maintenance
Freezer Condensing Unit Features
comparatively simple structure,easy for installation and maintenance;single compressor with small capacity is available,providing more combinations and more flexibility.
Freezer Condensing Unit Specifications
Model | Condensing TempTk | Coolingcapacity(Kw) under different Evaporating temp. | Compressor motor | air-cooled Condenser | Connection size | Overall | Operating weight (kg) |
||||
C | +7℃ | 0℃ | -10℃ | (Kw) |
Airflow (M3/h) |
Power (w) |
Suction pipe (mm) |
Supply pipe (mm) |
Dimension (L×W×H) |
||
ECBL-5A | 40 | 7.5 | 5.1 | 3.7 | 3.75 | 4840*1 | 230*1 | 28 | 10 | 860*900*800 | 204 |
45 | 6.9 | 4.6 | 3.3 | 7800*1 | 600*1 | 750*800*723 | 190 |
Stable & Reliable Performance
The unit comes standard with a controller that can effectively avoid turning on/off the motor
frequently as well as safety protection modules including the following: Phase loss protector,
Inverted sequence, overvoltage protector, undervoltage protector, oil pressure, high pressure,
low pressure, motor overload.
High efficiency oil separating system. When power is on, there is no need to add lubricating oil,
the standard provided oil heater (for screw unit), oil temperature controller (for screw unit) and
oil level switch (for screw unit), etc. can protect the function.
The PLC controller is a standard provided component. It can automatically decide the compressor
quantity to be used based on actual need of refrigerant capacity, average the running time
between each compressor, save the power. All of these will guarantee an over 30% longer
usage than single compressor condensing unit.
It has a unique low environment condensing pressure monitor system which guarantees a stable
functioning when there is a low ambient temperature, lack of oil feeding or oil flow warnin
High efficiency gas liquid separator is used, with a unique pipeline design, it can effectively
minimize the possibility of liquid strike.
The “Pressure Vessel Certificate” approved reservoir is provided as well as the safety relief valve.
Fault isolation device is served so that when a certain compressor breaks down, the rest of the
unit can keep running appropriately, making sure that client has enough time for repair and
replacement.
ECOOL Compressor Unit Advantages
Reliable quality
Every product is tested strictly before getting out of factory including noise test, vibration test, performance test.
Easy operation
Condenser, compressor and control box are in the same box of condensing unit, easy for maintenance and operation
Energy saving.
The design makes the unit automatically change the working numbers of compressor depending on system load, which can save your running cost.